What Are the Signs of a Failing Backflow Preventer? A Los Angeles Guide by Atlas Backflow Services

  • bill57931
  • 5 hours ago
  • 5 min read
ree

Backflow preventers are the quiet guardians of your drinking water, sitting between your property and the public water system to stop contaminated water from reversing direction. When they start to fail, the warning signs can be subtle—until they’re not.


Knowing what to watch for can save you from compliance issues, expensive repairs, and potential health risks. Below, Atlas Backflow Services shares the most common symptoms, what they mean, and what our Backflow Testing Los Angeles experts recommend you do next.


Quick answer: Top signs to watch for


  • Unexpected water discharge from the relief valve or air vent

  • Pressure changes: low, fluctuating, or erratic water pressure on your property

  • Discolored, cloudy, or bad-tasting water

  • Visible leaks, corrosion, or constant dampness around the assembly

  • Noisy operation: hammering, chattering, or whistling near the device

  • Stuck or hard-to-operate shutoff valves

  • Frequent irrigation or fire system issues

  • Failed or missing annual test tag


If you notice one or more of these, our Backflow Testing Los Angeles experts recommend scheduling a professional test immediately to confirm performance and protect your water.


Why backflow preventers fail


A backflow prevention assembly (RP, DC, PVB, or SVB) has springs, checks, seals, and relief mechanisms working together under pressure. Over time, those parts wear out, especially in Los Angeles where hard water and seasonal debris are common.


Common culprits include:


  • Mineral buildup and debris that pit seats and prevent tight sealing

  • Aging springs and seals that fatigue and lose tension

  • Corrosion from weather exposure or irrigation overspray

  • Water pressure fluctuations from main breaks or pump cycling

  • Improper installation or lack of maintenance


Our Backflow Testing Los Angeles experts recommend testing annually and after any major plumbing changes to catch wear early, make small repairs, and keep your assembly compliant.


Sign 1: Persistent dripping or sudden discharge


A reduced pressure (RP) assembly’s relief valve will vent water by design when it detects a problem. But:


  • Steady weeping or pooling water under the relief valve suggests a check isn’t sealing tight.

  • Sudden heavy discharge can indicate a large pressure imbalance, debris on the check seat, or a failing relief valve.


What to do: Do not cap or plug the relief port. Our Backflow Testing Los Angeles experts recommend shutting water to the device if discharge is heavy and calling for testing and repair. Capping is dangerous and violates code.


Sign 2: Low or fluctuating water pressure


Backflow devices add a small, normal pressure drop. But if you notice:


  • Noticeable pressure loss at fixtures or irrigation zones

  • Pressure oscillation when equipment cycles on and off


You may have a fouled check, partially closed shutoff, or debris restricting flow. Our Backflow Testing Los Angeles experts recommend a gauge check at hose bibs and a certified performance test to isolate the cause.


Sign 3: Discolored, cloudy, or odd-tasting water


Any change in water quality is a red flag for cross-connection hazards:


  • Yellow, brown, or cloudy water could indicate sediment or intrusion.

  • Chemical or metallic taste/odor may point to a cross-connection with irrigation, boiler, or process water.


Call your water provider if widespread; if it’s site-specific, our Backflow Testing Los Angeles experts recommend immediate testing and a cross-connection review.


Sign 4: Visible corrosion, leaks, or damp soil


  • Green/white scale, rust, or pinhole leaks on the body, unions, or test cocks mean the assembly’s integrity is compromised.

  • Constant damp earth around buried or partially buried devices suggests ongoing leakage.


Corroded components can fail without warning. Schedule a repair or replacement before the device is needed in an actual backflow event.


Sign 5: Noisy operation: chattering, hammering, or whistling


  • Chattering often points to unstable pressures or a weak spring.

  • Whistling may indicate restricted flow or partially closed valves.

  • Water hammer can damage internal components over time.


Our Backflow Testing Los Angeles experts recommend verifying upstream PRVs, pumps, and downstream equipment settings and testing the assembly under stable pressure.


Sign 6: Hard-to-turn or stuck shutoff valves


If the device’s inlet/outlet shutoff handles are frozen or excessively stiff:


  • Maintenance has likely been deferred.

  • Testing and emergency isolation become risky.


Our Backflow Testing Los Angeles experts recommend lubricating and exercising valves at least annually and replacing seized valves during service.


Sign 7: Irrigation or fire system trouble


  • Irrigation zones that won’t pressurize or take too long to fill can indicate a restrictive or failed PVB/RP.

  • Fire sprinkler trouble signals related to backflow assemblies should be addressed immediately to maintain life safety compliance.


Coordinate with your landscaper or fire contractor. We can test, repair, and document corrections for your AHJ or water purveyor.


Sign 8: Failed, expired, or missing test tag


If the tag is missing, unreadable, or shows a failure:


  • You may be out of compliance with your water purveyor or Title 17 requirements.

  • The assembly’s performance is unverified.


Our Backflow Testing Los Angeles experts recommend testing 30 days before your due date to allow time for repairs without risking fines or shutoffs.


What to do if you suspect failure


  • Do not bypass or remove the device; it’s your primary barrier against contamination.

  • Note the symptoms: pressure changes, leaks, noise, or water quality issues.

  • Call Atlas Backflow Services: We’ll perform a certified test with calibrated gauges, diagnose the issue, and complete repairs if needed.

  • Document everything: We submit the test report to your water authority and leave an updated tag.


If the assembly is beyond repair due to age, corrosion, or unavailable parts, our Backflow Testing Los Angeles experts recommend replacing with the correct device type and size for your hazard level and flow demand.


Preventive steps to avoid failures


  • Annual testing: Non-negotiable for compliance and early detection.

  • Keep devices accessible and above grade: Avoid burial or obstructed enclosures that trap moisture.

  • Install strainers upstream where debris is common.

  • Control pressure: Use PRVs to stabilize high or fluctuating supply pressure.

  • Protect from weather: Enclosures for freeze and sun exposure; prevent irrigation overspray.

  • After plumbing changes, retest: Remodels, new pumps, boilers, or irrigation additions can affect performance.


Our Backflow Testing Los Angeles experts recommend bundling multiple device tests on the same visit to reduce cost and site disruption.


Residential vs. commercial considerations


  • Homes and HOAs: Irrigation PVBs and RPs often show issues first—seasonal leaks, noisy vents, or weak zones. Check after long off-seasons.

  • Commercial/industrial: Larger RPs/DCs handle boilers, process water, and chemical injection; they need consistent maintenance and immediate attention to tags, logs, and notices.


Atlas Backflow Services works with homeowners, property managers, building engineers, and facility teams to tailor testing schedules and reminders.


FAQ


  • Can I fix a leaking backflow preventer myself? Minor fixes may look simple, but incorrect repairs can worsen failures or void compliance. Our Backflow Testing Los Angeles experts recommend certified testing and manufacturer-approved parts.

  • Why is my RP discharging intermittently? Pressure fluctuations or debris on the check seats are common. Testing will pinpoint whether cleaning, repair, or upstream pressure control is needed.

  • How long does a backflow preventer last? With proper maintenance, 5–15 years is typical. Harsh conditions and poor water quality shorten lifespan.


Protect your water with Atlas Backflow Services


Spotting early signs of a failing backflow preventer can prevent contamination, downtime, and fines. If you see leaks, pressure issues, discolored water, or a missing tag, our Backflow Testing Los Angeles experts recommend calling right away.


Atlas Backflow Services provides certified testing, on-the-spot repairs, compliant reporting, and proactive reminders—so your property stays protected and your drinking water stays clean.Ready to schedule or need a quick assessment? Contact Atlas Backflow Services to book your backflow test or inspection today.

 
 
 

Comments


Sunday

AVAILABLE BY APPOINTMENT or for emergencies, call (NO TXT) (562)343-1436 or txt (562)-304-3069 24 hrs a day

WORKING HOURS

Monday - Friday

7:00AM - 4:00PM for emergencies, call (NO TXT) (562)343-1436 or txt (562)-304-3069 24 hrs a day

Saturday

AVAILABLE BY APPOINTMENT or for emergencies, call (NO TXT) (562)343-1436 or txt (562)-304-3069 24 hrs a day

VISIT US

ATLAS BACKFLOW INC.

2852 Gundry Avenue, Signal Hill CA 90755

Office: (562) 343-1436 

Cell: (562) 304-3069

 

(Call or Text 24 hr's a day)

C-36 #1088210

  • Yelp
  • Facebook

GET IN TOUCH

Thanks for submitting!

© 2025 | Atlas Backflow Services

bottom of page