As a property owner or manager in Los Angeles, you know that water compliance is a serious business. You likely have a main backflow preventer near your water meter, which you have tested annually.


But what about the complex systems within your property? Do specific high-risk systems like irrigation lines, fire sprinklers, or commercial boilers require their own dedicated backflow preventers?


The short, unequivocal answer is yes. Not only is it a best practice for protecting your property's water supply, but it is also a legal requirement mandated by California plumbing codes and local water authorities like the Los Angeles Department of Water and Power (LADWP).These systems represent significant "cross-connections"—points where the clean, potable water supply could potentially come into contact with non-potable, contaminated water.


Without a dedicated backflow device at each of these points, you risk a serious public health incident and face significant compliance violations. Our backflow testing Los Angeles experts recommend that every property manager fully understands why each of these systems requires its own specific protection.


Let's break down the unique risks associated with each system and why a dedicated backflow preventer is non-negotiable.


1. Irrigation and Sprinkler Systems


This is perhaps the most common system requiring a backflow preventer, and for good reason. The water sitting in your irrigation lines is far from clean.


  • The Contaminants: Sprinkler heads sit in the dirt, exposed to fertilizers, pesticides, animal waste, and other ground contaminants. The water that sits stagnant in the underground pipes can also grow bacteria.

  • The Risk: A drop in pressure in the main water line—caused by a water main break down the street or even a fire hydrant being opened—can create a powerful back-siphonage effect. This can literally suck the contaminated water from your irrigation lines backward, past the meter, and into the public drinking water supply.

  • The Requirement: Because of this high degree of hazard, all irrigation systems must be isolated from the potable water supply with a dedicated backflow prevention assembly, such as a Pressure Vacuum Breaker (PVB) or a Reduced Pressure Zone (RPZ) device.


2. Commercial Fire Sprinkler Systems


You might think the water in a fire sprinkler system is just sitting there, clean and ready to go. The reality is quite different. Fire sprinkler systems are a major cross-connection concern.


  • The Contaminants: The water in a fire sprinkler system is often stagnant for years, if not decades. This allows for the growth of microorganisms and the leaching of oils, rust, and chemicals from the pipes themselves. Furthermore, many systems, especially in colder areas or freezers, contain antifreeze chemicals like propylene glycol. This chemically-treated water is not safe for consumption.

  • The Risk: Without a dedicated backflow preventer, any pressure fluctuation could draw this stagnant, chemically-treated water back into the building's drinking water system or the city main.

  • The Requirement: All commercial fire sprinkler systems require a specific type of backflow device, most commonly a Double Check Detector Assembly (DCDA). This device not only prevents backflow but also has a small, built-in water meter that can "detect" leaks or unauthorized water use from the fire system—a crucial feature for property management and water conservation.


3. Boilers and Hydronic Heating Systems


This applies mainly to commercial, industrial, and multi-family residential properties with central boiler systems for heat or hot water. The water inside a closed-loop boiler system is a chemical cocktail.


  • The Contaminants: To prevent corrosion and scaling inside the expensive boiler equipment, the water is treated with a variety of potent chemicals, including rust inhibitors, pH adjusters, and anti-scaling agents. This "boiler water" is highly toxic and completely unfit for human contact, let alone consumption.

  • The Risk: A boiler is directly connected to the potable water line to maintain its water level. If a backflow event occurs, it could siphon this toxic brew directly into the pipes that supply drinking fountains, sinks, and showers throughout the building. This represents one of the most severe health risks in a water system.

  • The Requirement: Because of the extreme hazard level, boiler systems require a high-level backflow prevention device, typically a Reduced Pressure Zone (RPZ) assembly. This device provides the maximum level of protection by not only having two independent check valves but also a relief valve that will open and dump the hazardous water out rather than ever let it pass back into the clean supply.


The Common Thread: Each Device Needs Separate Annual Testing


Here is the critical takeaway for property managers: Each of these dedicated backflow preventers is an independent, testable device.This means if your property has a main backflow preventer, one for the irrigation system, and one for the fire sprinkler system, you will receive three separate notices from the water utility.


You are legally required to have each one tested and certified annually by a licensed professional.Our backflow testing Los Angeles experts recommend creating a simple inventory of all backflow devices on your property and scheduling all your tests at the same time.


This proactive approach simplifies compliance and prevents any one system from falling through the cracks, which could lead to violation notices or fines.


Atlas Backflow Services: Your All-in-One Compliance Partner


Managing multiple backflow devices across different systems can feel overwhelming. At Atlas Backflow Services, we specialize in simplifying this process for Los Angeles property owners and managers.


  • Comprehensive Expertise: We are certified to test, repair, and install all types of backflow preventers, whether they are for domestic water, irrigation systems, fire sprinklers, or boilers.

  • Streamlined Service: We can test all the devices on your property in a single visit, minimizing disruption and ensuring complete compliance.

  • We Handle the Paperwork: Forget juggling multiple forms. After each successful test, we file all the necessary certification paperwork directly with the LADWP or your local water purveyor on your behalf.

  • Full-Service Repairs: If a device fails its test, our technicians are equipped with the parts and expertise to perform on-the-spot repairs, getting you back into compliance as quickly as possible.


Don't guess when it comes to the safety and compliance of your property's water systems. The rule is clear: if a system poses a risk, it needs its own dedicated and annually tested backflow preventer.


If you have questions about the devices on your property or have received a notice to test, contact the team at Atlas Backflow Services today. We are your trusted partner for all backflow testing needs in Los Angeles.

 
 
 

Comments


Sunday

AVAILABLE BY APPOINTMENT or for emergencies, call (NO TXT) (562)343-1436 or txt (562)-304-3069 24 hrs a day

WORKING HOURS

Monday - Friday

7:00AM - 4:00PM for emergencies, call (NO TXT) (562)343-1436 or txt (562)-304-3069 24 hrs a day

Saturday

AVAILABLE BY APPOINTMENT or for emergencies, call (NO TXT) (562)343-1436 or txt (562)-304-3069 24 hrs a day

VISIT US

ATLAS BACKFLOW INC.

2852 Gundry Avenue, Signal Hill CA 90755

Office: (562) 343-1436 

Cell: (562) 304-3069

 

(Call or Text 24 hr's a day)

C-36 #1088210

  • Yelp
  • Facebook

GET IN TOUCH

Thanks for submitting!

© 2025 | Atlas Backflow Services

bottom of page